ADDER AdderView CATxIP 000 Guide de l'utilisateur

Naviguer en ligne ou télécharger Guide de l'utilisateur pour Mise en réseau ADDER AdderView CATxIP 000. ADDER AdderView CATxIP 000 User guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 111
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs

Résumé du contenu

Page 1 - AdderView CATx

AdderView CATxUser Guide

Page 2 - Contents

 9Local userA locally connected video monitor, keyboard (and mouse) are required during the i

Page 3 - Further information

 99PortsIf you accept the analogy of IP addresses being rather like telephone numbers, then t

Page 4

 100Appendix 7 – Cable and connector specicationsRS232 serial mouse to PS/2 converter cable

Page 5 - Introduction

 101Multi-head synchronisation cableMASTER end9pin D-type maleSLAVE end9pin D-type maleMASTER

Page 6

 102Appendix 8 – Hotkey sequence codesThese codes are used when dening hotkey switching sequ

Page 7 - What’s in the box

 103Appendix 9 – Supported video modesThe following video modes are supported and can be auto

Page 8 - Installation

 104Safety information• For use in dry, oil free indoor environments only.• Both the AdderV

Page 9 - Connections

 105End user licence agreementPLEASE READ THIS AGREEMENT CAREFULLY. THIS AGREEMENT CONCERNS E

Page 10 - Local user

 106Radio Frequency EnergyA Category 5 (or better) twisted pair cable must be used to connect

Page 11

 107© 2006 Adder Technology LimitedAll trademarks are acknowledged.Release 1.0fJune 2006Part

Page 12 - Global user (IP network port)

 108HTIndexAAccesslocal and remote users 49via dial up link 64Access controlconguration 8

Page 13 - Computer system (via CAM)

 10Remote user (via X100 extender)Up to four users can be placed a maximum of 300 metres (980

Page 14 - Modem/ISDN port

 109IIdentitiesVNC Viewer 93Indicators 5,48Initialise button 86Initialize portlocal settin

Page 15 - Power in connection

 110VVideo compensation 27Video modes 103Video settings 62Viewer window 58VNC portinitial

Page 16 - Power control port

 11Global user (IP network port)The AdderView CATx IP models provide an autosensing Ethernet

Page 17 - Cascading multiple units

 12Computer system (via CAM)Each computer system is connected to the AdderView CATx unit via

Page 18

 13Modem/ISDN portThe AdderView CATx IP models provide a serial port to allow you to connect

Page 19

 14Power in connectionThe AdderView CATx unit is supplied with a single 30W power adapter whi

Page 20

 15Power control portThe AdderView CATx IP models provide a serial port for connection to one

Page 21 - Using cascaded computers

 16Cascading multiple unitsThe AdderView CATx (IP) units support up to sixteen or twenty four

Page 22

 17How cascade connections operateThe method for cascading AdderView CATx units is straightfo

Page 23 - Conguration

 18Addressing computers in a cascadeThe addressing format used by the AdderView CATx units in

Page 24 - Conguration menus

 1ContentsIntroductionAdderView CATx features - front and rear ...

Page 25 - Conguration menus layout

 193 Connect the other end of the cascade link cable to one of the CATx USER PORTS sockets o

Page 26

 20Using cascaded computersIn use, cascaded computers can be accessed using exactly the same

Page 27

 21Slave AdderView CATxMaster AdderView CATxMaster monitorSlave monitorComputers tted with d

Page 28 - Video compensation

 22CongurationAlmost all conguration and operational aspects of the AdderView CATx units ar

Page 29 - Computer video compensation

 23Conguration menusThe conguration menus allow you to determine many aspects of the AdderV

Page 30

 24Conguration menus layoutThe menu options are arranged as shown here:For a description of

Page 31 - Remote user skew adjustment

 25Registering users (edit user list)To create/edit user accounts1 Display the Conguration

Page 32

 26Registering computers (edit computer list)To create/edit computer entries1 Display the Co

Page 33 - Autoscanning

 27Video compensationThe AdderView CATx units allow computer systems to be placed up to 50m (

Page 34

 28Computer video compensationThe video compensation for connected computers is achieved usin

Page 35

 2OperationThe front panel controls ...

Page 36

 29To apply remote user video compensation1 Ensure that the video image from the computer to

Page 37 - Initial IP conguration

 30Remote user skew adjustmentThe category 5, 5e and 6 cabling supported by the AdderView CAT

Page 38

 313 As appropriate, press either the R, G or B keyboard keys to select the appropriate colo

Page 39 - Encryption settings

 32AutoscanningThe AdderView CATx provides an autoscan mode that switches between the connect

Page 40 - Networking issues

 33Saving and restoring conguration settingsThe AdderView CATx can store up to 512 computer

Page 41 - 192.168.47.10::11590

 34What to do if the ADMIN password has been forgottenIf the ADMIN password becomes mislaid o

Page 42

 35Hot plugging and mouse restorationIt is strongly recommended that you switch off a compute

Page 43

 36Initial IP congurationIP models of the AdderView CATx family possess a further collection

Page 44 - Pxy=z\0D

 37 To congure IP details from a global user location1 Use either the VNC viewer or a stan

Page 45 - The KVMADMIN utility

 38Encryption settingsThe AdderView CATx IP offers a great deal of exibility in its congura

Page 46 - Performing upgrades

 3Appendix 3 - VNC viewer connection options...90Colour/Encoding ...

Page 47

 39Networking issuesThanks to its robust security the AdderView CATx IP offers you great exi

Page 48

 40Placing AdderView CATx IP behind a router or rewallA possible point of contention between

Page 49

 41To discover a DHCP-allocated IP addressOnce a DHCP server has allocated an IP address, you

Page 50 - Local and remote user access

 42Placing AdderView CATx IP alongside the rewallAdderView CATx IP is built from the ground-

Page 51

 43Power switching congurationPower switch conguration comprises two main steps:• Congure

Page 52

 44The KVMADMIN utilityParticularly useful for complex AdderView CATx congurations and the c

Page 53 - The conrmation box

 45Performing upgradesThe AdderView CATx and CATx IP units are fully recongurable via ash u

Page 54 - Routing status

 469 - Commence the upgrade To begin the upgrade process, click the Upload Now button. The

Page 55

 47Upgrading AdderView CATx IP modelsThe AdderView CATx IP models are upgraded via global con

Page 56 - Global user access

 48OperationThe front panel controlsAdderView CATx modelsCOMPUTER button and numeric indicato

Page 57

 4IntroductionThank you for choosing the AdderView CATx series from Adder Technology. Each of

Page 58

 49This column shows the AdderView CATx address for each computer. If you wanted to select po

Page 59 - Using the viewer window

 50To select a computer using hotkeys1 Simultaneously press and hold and .Note: The and

Page 60 - Mouse pointers

 51To select a computer using the on-screen menu1 Select the on-screen menu in one of three

Page 61 - Re-synchronise mouse

 52Logging in and outThe AdderView CATx features a straightforward security system that helps

Page 62 - Controls

 53The reminder bannerAs many computer screen layouts can appear very similar, the AdderView

Page 63

 54Power switching (via conguration menu)When used in conjunction with optional power switch

Page 64

 55Global user accessGlobal users access the AdderView CATx IP using a viewer and a link. The

Page 65

 56IMPORTANT: During login, if you see a warning message similar to the one shown here, then

Page 66 - Supported web browsers

 57Global user access via web browserYou can use a standard Web browser (supported versions)

Page 67

 58Using the viewer windowThe viewer window gives you the ability to view and control the Add

Page 68

 5AdderView CATx features - front and rearThe AdderView CATx units pack a great deal of funct

Page 69 - Functions

 59Host selectionThe Hosts button on the menu bar provides the quickest and most efcient way

Page 70 - User Preferences

 60Access mode - shared/private Up to ve users can be simultaneously logged-on (four global

Page 71 - Global Preferences

 61Mouse ControlThis option displays a mouse control dialog and is useful when the remote cur

Page 72

 62Click to send the codeEnter the code hereKeyboard ControlThis option displays a keyboard c

Page 73 - Setup Options

 63Video SettingsThis dialog provides access to all of the key video settings that determine

Page 74 - Setup Options (continued)

 64If you need to enter a port numberUsually, when you make a network connection to the Adder

Page 75 - Advanced Options

 65Viewer encryption settingsThe web browser viewers and VNC viewers (of level 4.0b5S or high

Page 76 - Congure IP port

 66Further informationThis chapter contains a variety of information, including the following

Page 77 - Network Conguration

 67Appendix 1 – Conguration menusThe AdderView CATx conguration menus allow a range of sett

Page 78 - Reset Conguration

 68FunctionsThe Functions menu contains a collection of procedures that affect various aspect

Page 79 - Clearing IP access control

 6What’s in the boxAdderView CATx or AdderView CATx IP30W power adapter and country- specic

Page 80

 69User PreferencesThe User Preferences are system operating parameters that are independentl

Page 81 - User accounts

 70Global PreferencesGlobal preferences are available only to the Admin user and allow settin

Page 82 - Unit conguration

 71Global Preferences (continued)OSD Dwell TimeSettings: 1, 2, 3, 5, 10 SECONDSAfter a succes

Page 83 - Advanced unit conguration

 72Setup OptionsSetup options are available only to the Admin user and consist of key setting

Page 84 - Time & date conguration

 73Setup Options (continued)Automatic LogoutSettings: DISABLED, ENABLEDThe AdderView CATx ena

Page 85 - Network conguration

 74Advanced OptionsAdvanced options are available only to the Admin user and consist of setti

Page 86 - Setting IP access control

 75Congure IP portAvailable only on AdderView CATx IP models, the IP port conguration menu

Page 87 - Serial port conguration

 76Net MaskAlso often called the ‘subnet-mask’, this value is used alongside the IP address t

Page 88 - Host conguration

 77Modem CongurationThis page allows you to congure the COM1 serial port located at the rea

Page 89 - Adder Port Direct

 78Clearing IP access controlThis option removes all entries from the IP access control featu

Page 90 - Logging and status

 7InstallationMountingThe AdderView CATx units offer two main mounting methods:• Supplied fo

Page 91 - Colour/Encoding

 79Appendix 2 - Conguration pages via viewerThis section covers the conguration pages that

Page 92

 80User accountsThis page allows you to manage up to sixteen separate accounts. The rst of t

Page 93

 81Unit congurationThis page provides access to a selection of both basic and advanced setti

Page 94 - Load / Save

 82Advanced unit congurationClick this button to display advanced options that do not normal

Page 95

 83Time & date congurationThis page allows you to congure all aspects relating to time

Page 96 - Security

 84Network congurationThis page allows you to congure the various aspects of the IP port an

Page 97 - Net masks

 85Setting IP access controlThe golden rule with this feature is ‘Include before you exclude’

Page 98

 86Serial port congurationThis page provides all access to settings concerned with the two s

Page 99

 87Host congurationThis page provides the opportunity to congure various details for each o

Page 100 - Security issues with ports

 88Adder Port DirectAdder Port Direct is totally transparent communication system that allows

Page 101 - 

 8ConnectionsThe AdderView CATx and CATx IP units provide a great deal of exibility in their

Page 102

 89Logging and statusThis screen provides various details about the user activity on the Adde

Page 103 - Creating macro sequences

 90Appendix 3 - VNC viewer connection optionsWhen you are connecting to the AdderView CATx IP

Page 104

 91InputsEnable all inputsWhen selected, allows keyboard, mouse and clipboard data to be tran

Page 105 - Safety information

 92ScalingNo ScalingNo attempt is made to make the screen image t the viewer window. You may

Page 106 - End user licence agreement

 93IdentitiesThis feature helps your VNC viewer to conrm that a revisited AdderView CATx IP

Page 107 - Radio Frequency Energy

 94Appendix 4 - VNC viewer window optionsClick the VNC icon in the top left corner of the vie

Page 108

 95Appendix 5 - Browser viewer optionsWhen you are connecting to the AdderView CATx IP using

Page 109

 96Appendix 6 – Addresses, masks and portsIP address, network masks and ports are all closely

Page 110

 97Net masks - the binary explanationTo really understand the operation of a net mask it is n

Page 111

 98Calculating the mask for IP access controlThe IP access control function uses a standard I