Remote switching control
The port switching functions of the AdderView CATxIP
5000 unit can be remotely controlled by an RS232 link to
the OPTIONS port on the rear panel.
The sending device must use the following RS232
communication settings:
Baud rate: 19200 bps
Data bits: 8
Parity: None
Stop bits: 1
No handshaking is implemented, however, valid command characters will be
echoed back to the sending device.
Note: You must ensure that the AdderView CATxIP 5000 unit has it Options
serial ports set to ‘Sync Units’. This setting (together with the baud rate
selection) can be made either via the local or global user configuration menus.
The value of the byte received via the serial link determines which computer port
should be linked through to the user port. The table given here summarises the
valid control codes:
REMOTE
CONTROL
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 0
Local user 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 71
Host computer port/channel
(video off)
Cable from serial
control device
AdderView CATxIP 5000
rear panel