REMOTE module switches REMOTE module switches (continued)
REMOTE Switch 1
OFF: Normal operation.
ON: (Before power is applied) Places the REMOTE module into ash upgrade
mode so that the internal software can be changed. Please see the ‘Flash
upgrade’ section in the ‘Special conguration’ chapter.
REMOTE Switches 2 and 3
Switches 2 and 3 determine which two keyboard keys (when pressed in unison)
are to be designated as ‘hotkeys’. Hotkeys signal to the REMOTE module that
the next key to be pressed is a special conguration command for the module
and is not to be passed to the computer system.
2 OFF
3 OFF Hotkeys = CTRL and SHIFT
2 OFF
3 ON Hotkeys = ALT and SHIFT
2 ON
3 OFF Hotkeys = CTRL and ALT
2 ON
3 ON Hotkeys disabled
REMOTE Switch 4
This switch is reserved for future use.
Note: When shipped, all switches are set in the OFF positions and this will
produce normal operation.
Determines conguration
of hotkeys in conjunction
with switch 3
Reserved for
future use
OFF: Normal operation
ON: Flash upgrade
Determines conguration
of hotkeys in conjunction
with switch 2
1
O
N
2
3
4
1
ON
4
2
3
ON