3 Double-click on each screen representation to set the screen resolution and,
optionally, add a screen name and/or congure an LED monitor indicator:
See also Additional Free-
Flow operations and settings
The screen resolutions are not critical but they enable the CCS-PRO4 switch to
accurately map the movement of the mouse onto corresponding movements of the
pointer across the screens. The screen names, if used, are not downloaded to the
CCS-PRO4 switch.
If you need to congure an LED monitor indicator, click the LED Setup tab. Please see
Conguring LED monitor indicators for details.
4 When the screen map is complete and accurately matches the true layout of the
display screens, choose File > Save to store a copy of the layout. The layout will be
stored as a ‘Free-Flow Cong le’ with the extension: .ffc
5 To send the conguration, select Congure > Send Layout to Switch.
• If the download is successful, the screen representations will briey turn grey and
the upper four indicators on the CCS-PRO4 switch will begin to scroll across (they
will continue to do this while Free-Flow mode is enabled).
• If the download is unsuccessful, a message dialog will explain that it is ‘Unable to
communicate with the device’. Check the connection and the settings mentioned in
the section Installing the standard conguration application.